SECTION 12491 INTERIOR SUN CONTROL LOUVER SYSTEM ***** Skyshield International, Inc. manufacturers several types of aluminum skylight blinds and sun control shades. These include exterior and interior models with either manual or motorized operation. This guide specification section can be used to specify Skyshield 80 as manufactured by Skyshield International, Inc. Skyshield 80 is designed for installation on interior side of medium and large size rectangular skylights and window openings. Contact Skyshield International, Inc. for assistance in specifying other Skyshield models. The specification section is organized by placing information in three standard parts: PART 1 - GENERAL Describes administrative and procedural requirements. PART 2 - PRODUCTS Describes materials, products, and accessories to be incorporated into the construction project. PART 3 - EXECUTION Describes how the products will be installed at the construction site. Throughout this product guide specification, references are made to other specification sections that might be contained in the project manual. These references are presented as examples and coordination reminders. For each project, these references will need to be revised to reflect actual sections being used. Within the specification text, Imperial dimensions are presented first in brackets followed by System International Metric (SI) equivalents also in brackets. Depending on project requirements, either the Imperial or the SI metric equivalents will need to be deleted. The specifier will need to edit this product specification for a specific project to reflect the options and applications being used. The guide section has been written so that most editing can be accomplished by deleting unnecessary requirements and options. Depending on project requirements, some additional information will need to be added by the specifier. Options are indicated by [ ]. Notes to assist the specifier in selecting options and editing the specification guide are printed in bold and indicated with *****. For final editing, all brackets and notes will need to be deleted from the guide. *************************** PART 1 - GENERAL 1.1 SUMMARY ***** Skyshield 80 is designed for interior installation and can be either manually or electrically operated. Edit the following paragraph for the type of operation being specified and project conditions. ***** A. Section includes design and provision of [manually operated] [motorized, remotely controlled,] fully adjustable, aluminum slat, solar control louver system for mounting on interior side of [[sloped] [horizontal] [vertical]] [[skylights] [windows] [_____]. ***** List other specification sections dealing with work directly related to this section such as the following. ***** B. Related sections: 1. Section 08120 - Aluminum Doors and Frames: Glazed aluminum windows to receive solar control louver system. 2. Section 08410 - Metal Framed Storefronts: [Aluminum] [Steel] framing to receive solar control louver system. 3. Section 08600 - Skylights: Metal framed skylight to receive solar control louver system. 4. Section 08900 - Glazed Curtain Wall: Curtain wall system to receive solar control louver system. ***** Include the following paragraph if motorized louvers are being specified. ***** 5. Section 16100 - Wiring Methods: Electric supply, conduit, wiring, boxes, and wiring devices for motorized solar control louver system, by Section 16000 1.2 REFERENCES **** List by number and full title reference standards referred to in remainder of the specification section. Delete non-applicable references. ***** A. American Society for Testing and Materials (ASTM): 1. ASTM B209 - Aluminum and Aluminum-Alloy Sheet and Plate. 2. ASTM B221 - Aluminum Alloy Extruded Bar, Rod, Wire, Shape, and Tube.
A. Provide in accordance with Section 01330 - Submittal Procedures: 1. Product data listing components, operating hardware, [controls,] and accessories for louver system showing compliance with specified requirements. 2. Shop drawings showing layout, materials, dimensions, tolerances, [electrical connections, wiring diagrams,] method of anchorage, and installation details. 3. Louver system load calculations. 4. Samples: a. Finishes for selection by Architect. b. [6 inches] [150 mm] long louver slat sample with specified finish. 5. Installation, operation, and maintenance instructions. 1.4 QUALITY ASSURANCE A. Sole source responsibility: Complete sun control louver system including attachment hardware, operating mechanism, [controls] shall be provided by single firm to ensure compatibility of components and functional operation. B. Manufacturer: Company specializing in design and fabrication of operable sun control louver systems with 7 years minimum successful experience. C. Installer: Experienced in installing sun control louver systems of type specified and approved by louver manufacturer for installing system. D. Design and install sun control louver system to comply with seismic requirements for Project location. ***** Include the following paragraphs if motorized operation is required. ***** E. Motor operators shall be certified by Underwriters Laboratory (UL). F. Install electrical operators and controls in accordance with National Electric Code (NEC) requirements and local building codes.
A. Provide under provisions of Section 01780 - Closeout
Submittals: PARTS 2 - PRODUCTS 2.1 ACCEPTABLE MANUFACTURERS A. Only the products provided by one of the following manufacturers are acceptable:
1. Skyshield International, Inc., 3567 91st Street North, Suite
4, Lake Park, Fl. 33403. Phone: 888-640-0850. Estimating:
561-656-2556, FAX: 561-656-2599 B. Requests to use equivalent products of other manufacturers must be submitted in accordance with Section 01630 - Product Substitution Procedures. 2.2 SUN CONTROL LOUVER SYSTEM A. Type: Size 80 MM, custom shop fabricated, [manually operated] [motorized, remotely controlled,] solar control louver system consisting of extruded aluminum rack assembly and fully adjustable aluminum louver slats; Skyshield 80 as manufactured by Skyshield International, Inc. ***** Skyshield 80 is designed for medium and large size skylight and window openings. It can be installed in horizontal, vertical, and sloped positions. Drawings should indicate size, layout, and spacing of rack assembly arms. ***** B. Size, configuration, and layout: [Horizontal] [Vertical] [Sloped] installation as indicated on Drawings. C. Rack assembly: 1. Support arms: T shaped, [5/16 inch] [8 mm] thick, aluminum
extrusions complying with ASTM B221, 6063-T5 alloy and temper,
with [1 inch] [25 mm] nominal height by length required to span
opening. Provide arms with grooves to receive louver slats.
Space arms at [36 inches] [914 mm] maximum. D. Auxiliary support framing: Where required by Project conditions design and provide aluminum channels and angles as louver system support framing. E. Support brackets: Provide brackets for anchoring louver rack assembly to support framing. Coordinate provision of brackets with framing specified in [Section 05100 - Structural Metal Framing] [Section 08410 - Metal Framed Storefronts] [Section 08600 - Skylights] [Section 08900 - Glazed Curtain Wall] [_____]. 1. Type: Aluminum fabrications of type, size, and spacing to accommodate louver system and Project conditions. Threaded rod design shall allow height adjustment. Brackets to be adjustable laterally and transversely to align rack support arms. 2. Provide brackets with appropriate fasteners for attachment to support framing. 3. Space brackets as required to suspend rack support arms without sagging. a. Maximum arm spacing: [55 inches] b. Maximum arm overhang: [20 inches] F. Louver slats: Fabricate from [0.008 inch] [0.2 mm] minimum spring tempered magnesium aluminum alloy complying with ASTM B209. 1. Nominal width: [3-5/32 inches] [80 mm]. 2. Provide with [5/32 inch] [4 mm] radiused corners. G. Finish: 1. Louver slats and rack support arms: Thermoset enamel paint finish with color as selected by Architect from manufacturer's full range. 2. Brackets and other attachment components: Mill finish aluminum. H. Fabrication: Preassemble louver system at factory. Minimize requirements for field splicing and assembly. Disassemble units as required for shipping and handling. Label units for reassembly and installation at site.
***** Include this article to specify manual operation. ***** A. Provide manual operators for sun control louver system. Operator to permit variable shading angles plus fully opened and closed positions. B. Gear box: 5 to 1 ratio gear with steel or brass parts. C. Provide detachable rod and handle for inserting into gear box. Length to be sufficient for operating louver system from floor position. 2.4 MOTORIZED OPERATION AND CONTROLS ***** Include this article to specify motorized operation. ***** A. Sun control louver system shall be electrically operated and allow variable shading angles plus fully opened and closed positions. B. Motor: Isochronous capacitor start and run type, single phase, 120VDC, 60 Hz, 0.75 amp. Motor to be UL listed, thermally protected, totally enclosed, brushless type equipped with permanently lubricated bearing not requiring maintenance. Motor speed adjustable for synchronization of multiple louvers. C. Brake: Solenoid activated, disc type brake to automatically stop and hold louvers in any position without slippage when current to motor is interrupted. D. Limit switches: Adjustable thumbscrews for setting limits in both open and close directions. E. Gear box: Motor driven, 5 to 1 ratio gear with steel or brass parts. ***** Skyshield International, Inc, provides various methods for controlling motorized Skyshield 80. These include manual toggle switches, automatic light sensitive controls, and clock time controls. Select one of the following paragraphs to reflect type of controls required for motorized systems. ***** ***** Include the following paragraph if toggle switch controls are required. A single switch can control all louvers or multiple switches can be used to control groups of louvers. ***** F. Manual switch control: Provide electric toggle switches for opening and closing louvers and positioning louvers at any angle. [Control each louver individually with a separate toggle switch.] [Control multiple louvers from single switch in groups as indicated on Drawings and approved shop drawings.]
G. Sunlight sensor control: Provide external photocell to control louver system by opening and closing louvers to preset limits; Control T200 as furnished by Skyshield International, Inc. ***** Include the following paragraph if louver system is to be controlled by internal light sensor such that light level within building is maintained at a constant level. ***** H. Internal photocell control: Provide internal photocell to control louver system by positioning louvers such that light level within building is maintained at constant level; Control T300 as furnished by Skyshield International, Inc. ***** Include the following paragraph if louver system is be
controlled by timer. ***** PART 3 - EXECUTION 3.1 PREPARATION A. Field verify dimensions prior to commencing fabrication. ***** Include the following paragraph if motorized louvers are specified. ***** B. Coordinate electrical requirements to ensure proper power supply is provided for motorized operators. C. Examine site conditions and verify that support elements are properly sized, prepared, and ready to receive louver system. 3.2 INSTALLATION A. Install in accordance with manufacturer's instructions and approved shop drawings. Coordinate with installation of [skylight,] [windows,] [electrical power supply,] and ceiling and wall finishes. B. Accurately space and securely attach brackets to support structure. Connect louver rack assembly arms to brackets. C. Adjust threaded bracket suspension rods to ensure louvers
are [level] [vertical] [sloped at proper angle] and rack
assembly arms are correctly spaced and aligned. D. Closely fit joints of exposed connections. Ensure that
exposed to view connections are uniform and neat. ***** Include the following paragraph if motorized louvers are specified. ***** E. Install motor[s] on rack assembly arms and connect to drive shaft. Install control mechanisms at locations indicated on approved shop drawings and make electrical power connections. 3.3 TESTING, ADJUSTING, AND DEMONSTRATING A. After installation, test louver operation. Cycle louvers open and close a minimum of five times. Verify opening and closing operation and that movement limits are accurately and uniformly set. Verify louvers do not bind. ***** Include the following paragraph if motorized louvers are specified. ***** B. Verify that control mechanisms function properly. [Test automatic [photocell] [clock timer] and ensure louver movement is correctly controlled.] C. Correct deficiencies, adjust system for smooth operation, and retest. D. Demonstrate operation and maintenance of sun control louver system to Owner's representative. 3.4 TOUCH-UP AND CLEANING A. Touch-up finishes damaged during handling and installation with paint provided by manufacturer to match original finish. Items that cannot be satisfactorily refinished in field and bent or deformed components shall be removed and replaced. B. Remove protective materials from surfaces.
END OF SECTION |
|
|
|