Specifications:
Skyshield 90
SECTION
12491
INTERIOR
SUN CONTROL LOUVER SYSTEM
*****
Skyshield International, Inc. manufacturers several types of
aluminum skylight blinds and sun control shades. These include
exterior and interior models with either manual or motorized
operation. This guide specification section can be used to
specify Skyshield 90 as manufactured by Skyshield International,
Inc. Skyshield 90 is designed for installation on interior side
of medium and large size rectangular skylights and window
openings. Contact Skyshield International, Inc. for assistance
in specifying other Skyshield models.
The
specification section is organized by placing information in
three standard parts:
PART
1 - GENERAL Describes administrative and procedural
requirements.
PART
2 - PRODUCTS Describes materials, products, and accessories to
be incorporated into the construction project.
PART
3 - EXECUTION Describes how the products will be installed at
the construction site.
Throughout
this product guide specification, references are made to other
specification sections that might be contained in the project
manual. These references are presented as examples and
coordination reminders. For each project, these references will
need to be revised to reflect actual sections being used.
Within
the specification text, Imperial dimensions are presented first
in brackets followed by System International Metric (SI)
equivalents also in brackets. Depending on project requirements,
either the Imperial or the SI metric equivalents will need to be
deleted.
The
specifier will need to edit this product specification for a
specific project to reflect the options and applications being
used. The guide section has been written so that most editing
can be accomplished by deleting unnecessary requirements and
options. Depending on project requirements, some additional
information will need to be added by the specifier. Options are
indicated by [ ]. Notes to assist the specifier in selecting
options and editing the specification guide are printed in bold
and indicated with *****. For final editing, all brackets and
notes will need to be deleted from the guide.
***************************
PART
1 - GENERAL
1.1
SUMMARY
*****
Skyshield 90 is designed for interior installation and can be
either manually or electrically operated. Edit the following
paragraph for the type of operation being specified and project
conditions. *****
A.
Section includes design and provision of [manually operated]
[motorized, remotely controlled,] fully adjustable, aluminum
slat, solar control louver system for mounting on interior side
of [[sloped] [horizontal] [vertical]] [[skylights] [windows]
[_____].
*****
List other specification sections dealing with work directly
related to this section such as the following. *****
B.
Related sections:
1.
Section 08120 - Aluminum Doors and Frames: Glazed aluminum
windows to receive solar control louver system.
2.
Section 08410 - Metal Framed Storefronts: [Aluminum] [Steel]
framing to receive solar control louver system.
3.
Section 08600 - Skylights: Metal framed skylight to receive
solar control louver system.
4.
Section 08900 - Glazed Curtain Wall: Curtain wall system to
receive solar control louver system.
*****
Include the following paragraph if motorized louvers are being
specified. *****
5.
Section 16100 - Wiring Methods: Electric supply, conduit,
wiring, boxes, and wiring devices for motorized solar control
louver system, by Section 16000
1.2
REFERENCES
****
List by number and full title reference standards referred to in
remainder of the specification section. Delete non-applicable
references. *****
A.
American Society for Testing and Materials (ASTM):
1.
ASTM B209 - Aluminum and Aluminum-Alloy Sheet and Plate.
2.
ASTM B221 - Aluminum Alloy Extruded Bar, Rod, Wire, Shape, and
Tube.
1.3
SUBMITTALS
A.
Provide in accordance with Section 01330 - Submittal Procedures:
1.
Product data listing components, operating hardware, [controls,]
and accessories for louver system showing compliance with
specified requirements.
2.
Shop drawings showing layout, materials, dimensions, tolerances,
[electrical connections, wiring diagrams,] method of anchorage,
and installation details.
3.
Louver system load calculations.
4.
Samples:
a.
Finishes for selection by Architect.
b.
[6 inches] [150 mm] long louver slat sample with specified
finish.
5.
Installation, operation, and maintenance instructions.
1.4
QUALITY ASSURANCE
A.
Sole source responsibility: Complete sun control louver system
including attachment hardware, operating mechanism, [controls]
shall be provided by single firm to ensure compatibility of
components and functional operation.
B.
Manufacturer: Company specializing in design and fabrication of
operable sun control louver systems with 7 years minimum
successful experience.
C.
Installer: Experienced in installing sun control louver systems
of type specified and approved by louver manufacturer for
installing system.
D.
Design and install sun control louver system to comply with
seismic requirements for Project location.
*****
Include the following paragraphs if motorized operation is
required. *****
E.
Motor operators shall be certified by Underwriters Laboratory
(UL).
F.
Install electrical operators and controls in accordance with
National Electric Code (NEC) requirements and local building
codes.
1.5
WARRANTIES
A.
Provide under provisions of Section 01780 - Closeout Submittals:
1. 5 years manufacturer's warranty to cover sun control louver
system against manufacturing defects. 2 years on electrical
components & motors 2. 1 year installer's warranty to cover
defects in installation of system.
PARTS
2 - PRODUCTS
2.1
ACCEPTABLE MANUFACTURERS
A.
Only the products provided by the following manufacturers are
acceptable:
1.
Skyshield International, Inc., 3567 91st Street North, Suite 4,
Lake Park, Fl. 33403. Phone: 888-640-0850. Estimating:
561-656-2556, FAX: 561-656-2599. Website: www.shutterstudio.com 2. Abercrombe Sun
Control Division, Atlanta Georgia.
B.
Requests to use equivalent products of other manufacturers must
be submitted in accordance with Section 01630 - Product
Substitution Procedures.
2.2
SUN CONTROL LOUVER SYSTEM
A.
Type: Size 90 MM custom shop fabricated, [manually operated]
[motorized, remotely controlled,] solar control louver system
consisting of extruded aluminum rack assembly and fully
adjustable aluminum louver slats; Skyshield 90 as manufactured
by Skyshield International, Inc.
*****
Skyshield 90 is designed formaximum shading of medium and large
size skylight and window openings. It can be installed in
horizontal, vertical, and sloped positions. Drawings should
indicate size, layout, and spacing of rack assembly arms. *****
B.
Size, configuration, and layout: [Horizontal] [Vertical]
[Sloped] installation as indicated on Drawings.
C.
Rack assembly:
1.
Support arms: T shaped, [5/16 inch] [8 mm] thick, aluminum
extrusions complying with ASTM B221, 6063-T5 alloy and temper,
with [1 inch] [25 mm] nominal height by length required to span
opening. Provide arms with grooves to receive louver slats.
Space arms at [36 inches] [914 mm] maximum. 2. Slat holders:
Carbon impregnated, nylon holder to receive aluminum slats with
nylon pivot fastened into support arm groove. 3. Drive shaft:
Hexagonal aluminum tube connected to slat holders. Rotating
drive shaft tilts louver slats.
D.
Auxiliary support framing: Where required by Project conditions
design and provide aluminum channels and angles as louver system
support framing.
E.
Support brackets: Provide brackets for anchoring louver rack
assembly to support framing. Coordinate provision of brackets
with framing specified in [Section 05100 - Structural Metal
Framing] [Section 08410 - Metal Framed Storefronts] [Section
08600 - Skylights] [Section 08900 - Glazed Curtain Wall]
[_____].
1.
Type: Aluminum fabrications of type, size, and spacing to
accommodate louver system and Project conditions. Threaded rod
design shall allow height adjustment. Brackets to be adjustable
laterally and transversely to align rack support arms.
2.
Provide brackets with appropriate fasteners for attachment to
support framing.
3.
Space brackets as required to suspend rack support arms without
sagging.
a.
Maximum arm spacing: [40 inches]
b.
Maximum arm overhang: [12 inches]
F.
Louver slats: Fabricate from [0.008 inch] [0.2 mm] minimum
spring tempered magnesium aluminum alloy complying with ASTM
B209.
1.
Nominal width: [3-1/2 inches] [90 mm].
2.
Provide with [5/32 inch] [4 mm] radiused corners.
G.
Finish:
1.
Louver slats and rack support arms: Thermoset enamel paint
finish with color as selected by Architect from manufacturer's
full range.
2.
Brackets and other attachment components: Mill finish aluminum.
H.
Fabrication: Pre-assemble louver system at factory. Minimize
requirements for field splicing and assembly. Disassemble units
as required for shipping and handling. Label units for
reassembly and installation at site.
2.3
MANUAL OPERATOR
*****
Include this article to specify manual operation. *****
A.
Provide manual operators for sun control louver system. Operator
to permit variable shading angles plus fully opened and closed
positions.
B.
Gear box: 5 to 1 ratio gear with steel or brass parts.
C.
Provide detachable rod and handle for inserting into gear box.
Length to be sufficient for operating louver system from floor
position.
2.4
MOTORIZED OPERATION AND CONTROLS
*****
Include this article to specify motorized operation. *****
A.
Sun control louver system shall be electrically operated and
allow variable shading angles plus fully opened and closed
positions.
B.
Motor: Isochronous capacitor start and run type, single phase,
120VDC, 60 Hz, 0.75 amp. Motor to be UL listed, thermally
protected, totally enclosed, brushless type equipped with
permanently lubricated bearing not requiring maintenance. Motor
speed adjustable for synchronization of multiple louvers.
C.
Brake: Solenoid activated, disc type brake to automatically stop
and hold louvers in any position without slippage when current
to motor is interrupted.
D.
Limit switches: Adjustable thumbscrews for setting limits in
both open and close directions.
E.
Gear box: Motor driven, 5 to 1 ratio gear with steel or brass
parts.
*****
Skyshield International, Inc, provides various methods for
controlling motorized Skyshield 90. These include manual toggle
switches, automatic light sensitive controls, and clock time
controls. Select one of the following paragraphs to reflect type
of controls required for motorized systems. *****
*****
Include the following paragraph if toggle switch controls are
required. A single switch can control all louvers or multiple
switches can be used to control groups of louvers. *****
F.
Manual switch control: Provide electric toggle switches for
opening and closing louvers and positioning louvers at any
angle. [Control each louver individually with a separate toggle
switch.] [Control multiple louvers from single switch in groups
as indicated on Drawings and approved shop drawings.]
*****
Include the following paragraph if louver system is to be
controlled by exterior light sensor. *****
G.
Sunlight sensor control: Provide external photocell to control
louver system by opening and closing louvers to preset limits;
Control T200 as furnished by Skyshield International, Inc.
*****
Include the following paragraph if louver system is to be
controlled by internal light sensor such that light level within
building is maintained at a constant level. *****
H.
Internal photocell control: Provide internal photocell to
control louver system by positioning louvers such that light
level within building is maintained at constant level; Control
T300 as furnished by Skyshield International, Inc.
*****
Include the following paragraph if louver system is be
controlled by timer. ***** I. Clock timer: Provide clock timer
to open and close louvers at pre-selected times; Control T210 as
furnished by Skyshield International, Inc.
PART
3 - EXECUTION
3.1
PREPARATION
A.
Field verify dimensions prior to commencing fabrication.
*****
Include the following paragraph if motorized louvers are
specified. *****
B.
Coordinate electrical requirements to ensure proper power supply
is provided for motorized operators.
C.
Examine site conditions and verify that support elements are
properly sized, prepared, and ready to receive louver system.
3.2
INSTALLATION
A.
Install in accordance with manufacturer's instructions and
approved shop drawings. Coordinate with installation of
[skylight,] [windows,] [electrical power supply,] and ceiling
and wall finishes.
B.
Accurately space and securely attach brackets to support
structure. Connect louver rack assembly arms to brackets.
C.
Adjust threaded bracket suspension rods to ensure louvers are
[level] [vertical] [sloped at proper angle] and rack assembly
arms are correctly spaced and aligned.
D.
Closely fit joints of exposed connections. Ensure that exposed
to view connections are uniform and neat.
*****
Include the following paragraph if motorized louvers are
specified. *****
E.
Install motor[s] on rack assembly arms and connect to drive
shaft. Install control mechanisms at locations indicated on
approved shop drawings and make electrical power connections.
3.3
TESTING, ADJUSTING, AND DEMONSTRATING
A.
After installation, test louver operation. Cycle louvers open
and close a minimum of five times. Verify opening and closing
operation and that movement limits are accurately and uniformly
set. Verify louvers do not bind.
*****
Include the following paragraph if motorized louvers are
specified. *****
B.
Verify that control mechanisms function properly. [Test
automatic [photocell] [clock timer] and ensure louver movement
is correctly controlled.]
C.
Correct deficiencies, adjust system for smooth operation, and
retest.
D.
Demonstrate operation and maintenance of sun control louver
system to Owner's representative.
3.4
TOUCH-UP AND CLEANING
A.
Touch-up finishes damaged during handling and installation with
paint provided by manufacturer to match original finish. Items
that cannot be satisfactorily refinished in field and bent or
deformed components shall be removed and replaced.
B.
Remove protective materials from surfaces.
END